If you found this page, you probably have a problem and you need a user manual for the device HP (Hewlett-Packard) HP ProLiant 2U Rack Server 662257-001. Be sure to check that it is the user manual to exactly the device that you are looking for. In our database HP (Hewlett-Packard) HP ProLiant 2U Rack Server 662257-001 it belongs to the category Server. A user manualHP (Hewlett-Packard) HP ProLiant 2U Rack Server 662257-001 is taken from the manufacturer, a HP (Hewlett-Packard) company - it is an official document, so if you have any doubts as to its contents, please contact the manufacturer of the device HP (Hewlett-Packard) HP ProLiant 2U Rack Server 662257-001 directly. You can view the user manualHP (Hewlett-Packard) HP ProLiant 2U Rack Server 662257-001 directly online or save and store it on your computer.

Position  
Default  
Function  
Off  
Off = Power-on password is enabled.  
On = Power-on password is disabled.  
S5  
Off  
Off = No function  
S6  
On = ROM reads system configuration  
as invalid.  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
S7  
S8  
S9  
S10  
S11  
S12  
To access the redundant ROM, set S1, S5, and S6 to on.  
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all  
system configuration settings from both CMOS and NVRAM.  
CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to  
properly configure the server or data loss could occur.  
NMI functionality  
An NMI crash dump enables administrators to create crash dump files when a system is hung and not  
responding to traditional debug mechanisms.  
Crash dump log analysis is an essential part of diagnosing reliability problems, such as hangs in operating  
systems, device drivers, and applications. Many crashes freeze a system, and the only available action for  
administrators is to cycle the system power. Resetting the system erases any information that could support  
problem analysis, but the NMI feature preserves that information by performing a memory dump before a  
hard reset.  
To force the OS to invoke the NMI handler and generate a crash dump log, the administrator can use the iLO  
Virtual NMI feature.  
For more information, see the white paper on the HP website  
(http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf).  
Component identification 17  

In addition to the user manual HP (Hewlett-Packard) HP ProLiant 2U Rack Server 662257-001, we also provide a support panel to help you solve your problems with HP (Hewlett-Packard) HP ProLiant 2U Rack Server 662257-001. If you have any questions, you can ask them in the form below. Other users viewing this website will have the opportunity to help you solve your probem with HP (Hewlett-Packard) HP ProLiant 2U Rack Server 662257-001. Remember that you can also share the solution. If you solved the problem yourself, please write the solution to the problem with HP (Hewlett-Packard) HP ProLiant 2U Rack Server 662257-001 - you will surely help many users by doing so.