If you found this page, you probably have a problem and you need a user manual for the device CyberPower Sleep Apnea Machine AN1302. Be sure to check that it is the user manual to exactly the device that you are looking for. In our database CyberPower Sleep Apnea Machine AN1302 it belongs to the category Sleep Apnea Machine. A user manualCyberPower Sleep Apnea Machine AN1302 is taken from the manufacturer, a CyberPower company - it is an official document, so if you have any doubts as to its contents, please contact the manufacturer of the device CyberPower Sleep Apnea Machine AN1302 directly. You can view the user manualCyberPower Sleep Apnea Machine AN1302 directly online or save and store it on your computer.

Shutdown NAS in PowerPanel  
Introduction  
If you want to properly shut down both the computer and the NAS that are being supplied power by a UPS,  
this manual will guide through the necessary steps. This will allow the NAS to shut down via the SSH service  
and the computer to shut down gracefully.  
If you are only connecting a NAS to the UPS, you do not need this manual. Simply connect USB cable from  
the UPS to the NAS and refer to users manual for the NAS about power management instructions.  
Set-up  
1.  
Enable the SSH service on the NAS to allow remote SSH login.  
QNAP NAS Example:  
Log in to the QTS web service and enable Allow SSH connection from Control Panel > Network  
Services > Telnet/SSH.  
Synology NAS Example:  
Log in of the DSM web service and check Enable SSH Service from Control Panel > Terminal.  
(
Refers to your NAS user’s manual for more details about SSH service.)  
2.  
Make sure that the PowerPanel Software has been installed on your computer:  
PowerPanel Person Edition is used on Windows.  
PowerPanel for Mac is used on Mac OS X.  
PowerPanel for Linux is used on Linux.  
3
.
.
Plug in your NAS and computer to the UPS outlets labeled BATTERY/SURGE or CRITICAL LOAD.  
Connect the USB or serial cable between the UPS and the computer to allow PowerPanel to  
communicate with the UPS.  
4
5.  
Ensure that there is an active network connection between your computer and NAS.  
Configuration on Windows  
Download SSH client tool  
In order to remote control the NAS equipment via SSH service automatically, use plink.exe as the SSH client  
tool. Visit http://www.chiark.greenend.org.uk/~sgtatham/putty/download.html, click the download for plink.exe  
from the list and save it to your desired directory.  
Edit External Command of PowerPanel Personal Edition  
1.  
Go to PowerPanel Personal Edition installation directory, such as C:\Program Files(x86)\CyberPower  
PowerPanel Personal Edition is the default directory.  
2
.
.
Ensure that you are on an administrative permission.  
3
Edit default.cmd as shown below to allow the NAS to shutdown. Note that on older versions of Windows  
systems such as Win98 or ME, the filename may be default.bat.  
echo n | C:\plink.exesshpw AdminPassword AdminAccount@IpAddress poweroff  
2

In addition to the user manual CyberPower Sleep Apnea Machine AN1302, we also provide a support panel to help you solve your problems with CyberPower Sleep Apnea Machine AN1302. If you have any questions, you can ask them in the form below. Other users viewing this website will have the opportunity to help you solve your probem with CyberPower Sleep Apnea Machine AN1302. Remember that you can also share the solution. If you solved the problem yourself, please write the solution to the problem with CyberPower Sleep Apnea Machine AN1302 - you will surely help many users by doing so.