If you found this page, you probably have a problem and you need a user manual for the device Allied Telesis Switch X900-24XS. Be sure to check that it is the user manual to exactly the device that you are looking for. In our database Allied Telesis Switch X900-24XS it belongs to the category Switch. A user manualAllied Telesis Switch X900-24XS is taken from the manufacturer, a Allied Telesis company - it is an official document, so if you have any doubts as to its contents, please contact the manufacturer of the device Allied Telesis Switch X900-24XS directly. You can view the user manualAllied Telesis Switch X900-24XS directly online or save and store it on your computer.

Installation and Safety Guide  
Applying Power to the Switch  
Power supply bays are in the rear of the switch. Depending on the model, the  
switch may have a PSU, FOM, or blanking plate over a power supply bay.  
Connecting an AC power supply  
Follow these instructions to connect one of the following to an AC power supply:  
an AT-PWR01, AT-PWR02, or AT-PWR05 AC PSU  
an x900-12XT/S switch  
Warning The AT-PWR01 AC PSU has a fuse rating of 250V, 5A for FH101 and  
FH102.  
Warning The AT-PWR01 AC PSU has double pole/neutral fusing. Electric  
shock is possible since there are dual primary fuses, one on the phase circuit and  
one on the neutral circuit. If the neutral opens, the phase may still be live.  
Warning When x900-24 units are connected with VCS stacking cables (XEM-  
STK-CBL) ensure that all the PSUs are appropriately grounded. This is to avoid  
large circulating ground currents that could damage the stacking cables. To  
achieve this ensure that:  
AT-PWR01 AC is grounded by the 3-pin AC power connector  
All grounding points are at the same ground level. That is, all power  
connectors share a common power distribution unit.  
Warning For x900-24 models, when using an AT-PWR01 AC power supply and  
an AT-PWR01 DC power supply in the same switch, then the ground-terminal of  
the DC power connector must be connected to the same ground as the AC  
ground pin of the AC power connector.  
If this is not possible, then you must ground the AT-PWR01 AC only, and leave  
the AT-PWR01 DC power connector ungrounded. In this case, as a safety  
precaution, ensure that the rack is also grounded.  
Warning For SwitchBlade x908 AC models the grounding stud on the rear of  
the unit is for supplemental grounding only. The system must be supplied by a  
grounded 3 wire AC source through the power supply cord.  
Warning When SBx908 devices are connected with VCS stacking cables (either  
HS-STK-CBL or XEM-STK-CBL), each individual stack member chassis must be  
additionally grounded by using the rear grounding-terminal on each device. In  
order to avoid large circulating ground currents, the wires of each grounding  
cable must be 18AWG or thicker.  
1
1

In addition to the user manual Allied Telesis Switch X900-24XS, we also provide a support panel to help you solve your problems with Allied Telesis Switch X900-24XS. If you have any questions, you can ask them in the form below. Other users viewing this website will have the opportunity to help you solve your probem with Allied Telesis Switch X900-24XS. Remember that you can also share the solution. If you solved the problem yourself, please write the solution to the problem with Allied Telesis Switch X900-24XS - you will surely help many users by doing so.