Si has encontrado esta página, seguramente tienes un problema y necesitas el manual de instrucciones para el dispositivo Zanussi 102284. Recuerda comprobar si es el manual exacto para el dispositivo que buscas. En nuestra base Zanussi 102284 pertenece a la categoría Nevera. El manual Zanussi 102284 es del fabricante, la empresa Zanussi - es un documento oficial y si tienes alguna duda acerca de su contenido, contacta directamente con el fabricante del dispositivo Zanussi 102284. El manual Zanussi 102284 se puede ver directamente online o guardar y almacenar en tu ordenador.

RANGE  
COMPOSITION  
A complete and flexible range of cold rooms  
ideal for storing and conserving perishable  
food (meat, fish, cold cuts, cheese, fruit,  
vegetables), in addition to chilled and frozen  
food. Constructed in top quality, reliable  
materials, they are manufactured with the  
utmost attention paid to eliminting possible  
ecological damage. All models can be  
connected to a refrigeration unit installed  
directly inset on the wall of the cold room or  
to a remote refrigeration unit. The availability  
of a remote condenser unit is particularly  
useful when using cold rooms in  
environments with critical ambient  
temperatures, ventilation or space problems.  
The models detailed on this sheet are 3 cold  
rooms (-2°+8°C) with built-in refrigerating  
unit and with usable volume of 12 to 14 m³  
with panel insulation 60 mm in thickness. All  
models come with panels, gas precharged  
cooling unit and piping.  
Shelving as accessory  
1
2/ 14 m³  
ZANUSSI  
SPLIT UNIT COLD ROOMS -2º+8ºC  
P R O F E S S I O N A L  
entrapment when the door is accidentally  
locked from outside.  
indicator, temperature and thermostat control  
with digital display.  
All models comply with the standards  
required by the main international approval  
bodies and are H marked.  
FUNCTIONAL AND  
CONSTRUCTION  
FEATURES  
Powerful tropicalized refrigeration system  
designed to operate more efficiently and  
without failure in the most extreme  
temperatures (up to 43ºC).  
Assembly system that guarantees minimal  
Prefitted and insulated pipes for  
temperature loss through twin hook fasteners  
which allow perfect alignment of the panels.  
This fastener is made of high resistant  
composite material and guarantees perfect  
grip of all components that can be easely  
disassembled and reassembled.  
connection between evaporator and  
condensing unit with fast connectors.  
Defrosting through heated gas permits to  
reduce the total power installed shorten  
defrosting time and limited warming of the  
cold room.  
Wall panels and inside ceiling panels are  
The control panel includes: luminous  
cladded with anti-scratch prepainted  
galvanized steel  
ON/OFF switch, internal lighting switch, cold  
room functioning indicator, defrosting cycle  
All panels are insulated with injected  
polyurethane.CFC and HCFC free.  
All panels have PVC gaskets foamed in  
TECHNICAL DATA  
CHARACTERISTICS  
MODELS  
place to assure airtight and secure fitting.  
Any other sealing between panels on site is  
eliminated..  
MN12024RCL  
102280  
MN14028RCL  
102281  
MN14024RCL  
102284  
External dimensions - mm  
width  
depth  
2550  
2550  
2150  
2550  
2950  
2150  
2950  
2550  
2150  
Galvanized steel floor covered with a  
non-abrasive, non-slip, ribbed plastic coat  
height  
Rounded internal and external corners.  
The right-hinged door is available as  
Internal dimensions - mm  
width  
depth  
height  
Power - kW  
installed-electric  
Noise level - dBA  
Net weight - kg.  
Power supply - V, phases, Hz  
Usable surface area - m²  
Usable volume - m³.  
Refrigeration unit  
Compressor power - HP  
2430  
2430  
2030  
2430  
2830  
2030  
2830  
2430  
2030  
standard (left-hinghed door on request) and  
constructed with smooth rounded profiles,  
cam-lift action highes, airtight magnetic door,  
gaskets and high insulation for saving energy  
and operating costs. As an option a  
microswitch switches on automatically the  
internal light and turns off the fans  
1.2  
60  
499  
230 V, 1N, 50  
5,90  
12,0  
1.2  
60  
561  
230 V, 1N, 50  
6.88  
14,0  
1.2  
60  
564  
230 V, 1N, 50  
6,88  
14,0  
Newly designed handle, complete with  
lock has an internal safety release to prevent  
1,10  
1,10  
1,10  

Además del manual Zanussi 102284 facilitamos un panel de soporte que te ayudará a solucionar tus problemas con Zanussi 102284. Si tienes alguna pregunta, puedes escribirla en el formulario más abajo. Otros usuarios que entran aquí tendrán la oportunidad de ayudarte en la solución de tu problema con Zanussi 102284. Recuerda que también puedes compartir tu solución. Si has logrado solucionar el problema, por favor escribe aquí la descripción y la solución del problema con Zanussi 102284 - seguro que ayudarás a muchos usuarios.