このページへお越しの方は、おそらくデバイスWhirlpool GXW6530DXSに関する問題を抱えており、その説明書を必要としていることでしょう。お探しの説明書がお持ちのデバイスのそれであることを必ずご確認ください、お探しのWhirlpool GXW6530DXSは、このデータベースではカテゴリー範囲に属します。 説明書Whirlpool GXW6530DXSはメーカーWhirlpoolの発行するものです - これは公式文書であるため、その内容に疑問がある場合はデバイスWhirlpool GXW6530DXSの製造元に直接お問い合わせください。説明書Whirlpool GXW6530DXSはオンラインで直接見たりコンピュータにダウンロードし保存したりすることができます。

For Non-Vented (recirculating) Installations  
If it is not possible to vent cooking fumes and vapors to the  
outside, the hood can be used in the non-vented (recirculating)  
version, fitting a charcoal filter and the deflector. Fumes and  
vapors are recycled through the top grille.  
ElectricalRequirements  
Observe all governing codes and ordinances.  
Ensure that the electrical installation is adequate and in  
conformance with National Electrical Code, ANSI/NFPA 70 (latest  
edition), or CSA Standards C22.1-94, Canadian Electrical Code,  
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes  
and ordinances.  
Roof Venting  
Wall Venting  
Non-vented  
recirculating)  
(
A
A
If codes permit and a separate ground wire is used, it is  
recommended that a qualified electrician determine that the  
ground path is adequate.  
B
B
A copy of the above code standards can be obtained from:  
B
National Fire Protection Association  
1 Batterymarch Park  
A
Quincy, MA 02169-7471  
CSA International  
501 East Pleasant Valley Road  
8
Cleveland, OH 44131-5575  
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is  
required.  
If the house has aluminum wiring, follow the procedure  
below:  
A. Roof cap  
B. 6" (15.2 cm)  
round vent  
A. Wall cap  
B. 6" (15.2 cm)  
round vent  
A. Deflector  
B. 6" (15.2 cm)  
round vent  
1
.
Connect a section of solid copper wire to the pigtail  
leads.  
Connect the aluminum wiring to the added section of  
copper wire using special connectors and/or tools  
designed and UL listed for joining copper to aluminum.  
2.  
Calculating Vent System Length  
Follow the electrical connector manufacturer's recommended  
procedure. Aluminum/copper connection must conform with  
local codes and industry accepted wiring practices.  
To calculate the length of the system you need, add the  
equivalent feet (meters) for each vent piece used in the system.  
Wire sizes and connections must conform with the rating of  
the appliance as specified on the model/serial rating plate.  
The model/serial plate is located behind the filter on the rear  
wall of the range hood.  
Vent Piece  
6" (15.2 cm) Round  
4
5° elbow  
0° elbow  
2.5 ft  
(
0.8 m)  
Wire sizes must conform to the requirements of the National  
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA  
Standards C22. 1-94, Canadian Electrical Code, Part 1 and  
C22.2 No. 0-M91 (latest edition) and all local codes and  
ordinances.  
9
5.0 ft  
(1.5 m)  
Maximum equivalent vent length is 35 ft (10.7 m).  
Example vent system  
Wall cap  
90 elbow  
6 ft (1.8 m)  
2
ft  
(
0.6 m)  
The following example falls within the maximum recommended  
vent length of 35 ft (10.7 m).  
1
1
8
- 90° elbow  
= 5.0 ft (1.5 m)  
= 0.0 ft (0.0 m)  
= 8.0 ft (2.4 m)  
- wall cap  
ft (2.4 m) straight  
Length of system  
= 13.0 ft (3.9 m)  