5
.
.
Use UL listed wire connectors and connect black wires (C)
together.
MakeElectricalConnection
6
Use UL listed wire connectors and connect white wires (E)
together.
WARNING
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Electrical Shock Hazard
Replace all parts and panels before operating.
Electrically ground blower.
Failure to do so can result in death or electrical shock.
Connect ground wire to green and yellow ground wire
in terminal box.
1.
2.
3.
Disconnect power.
Failure to do so can result in death or electrical shock.
Remove terminal box cover.
Remove the knockout in the terminal box cover and install a
UL listed or CSA approved ¹⁄₂" strain relief.
7.
Connect green (or bare) ground wire from home power supply
to yellow-green ground wire (F) in terminal box using UL listed
wire connectors.
A
B
8. Tighten strain relief screw.
9
1
1
. Install terminal box cover.
0. Check that all light bulbs are secure in their sockets.
1. Reconnect power.
InstallVentCovers
When using both upper and lower vent covers, push lower cover
down onto hood and lift upper cover to ceiling and install with
2
- 4 x 8 mm screws.
NOTE: For vented installations, the upper vent cover may be
reversed to hide slots.
B
A. Knockout
B. Terminal box cover
4.
Run home power supply cable through strain relief, into
terminal box.
A
A
B
C
C
D
A. Bracket
B. 4 x 8 mm screws
C. Vent cover
E
F
A. Home power supply cable
B. UL listed or CSA approved strain relief
C. Black wires
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow-green ground wires