このページへお越しの方は、おそらくデバイスAllied Telesis Switch X900-24XSに関する問題を抱えており、その説明書を必要としていることでしょう。お探しの説明書がお持ちのデバイスのそれであることを必ずご確認ください、お探しのAllied Telesis Switch X900-24XSは、このデータベースではカテゴリースイッチに属します。 説明書Allied Telesis Switch X900-24XSはメーカーAllied Telesisの発行するものです - これは公式文書であるため、その内容に疑問がある場合はデバイスAllied Telesis Switch X900-24XSの製造元に直接お問い合わせください。説明書Allied Telesis Switch X900-24XSはオンラインで直接見たりコンピュータにダウンロードし保存したりすることができます。

Installation and Safety Guide  
Warning When SBx908 devices are connected with VCS stacking cables (either  
HS-STK-CBL or XEM-STK-CBL), each individual stack member chassis must be  
additionally grounded by using the rear grounding-terminal on each device. In  
order to avoid large circulating ground currents, the wires of each grounding  
cable must be 18AWG or thicker.  
PWR01 PWR01 DC  
DC  
Power supply specifications:  
functional range 40 to 60V, 48V nominal  
supports either positive grounded or negative grounded operation  
a 15Amp certified/listed circuit breaker is required for circuit protection  
Supply cable specifications:  
tray cable should be UL listed Type TC tray cable (or equivalent)  
three-core cable is required  
minimum core size: 3.3mm2 (12 AWG) high strand count copper wire  
minimum cable rating: 600V, 90 degrees C  
Warning Disconnect the power supply cable before starting this procedure.  
1
2
. Remove the transparent protective terminal cover.  
. Strip the supply cable wires to expose 7.5mm (0.31in.) of bare conductor.  
Terminate the wire with a nylon insulated solderless ring tongue terminal,  
JST FN5.5-5 or equivalent, using a crimp tool.  
3
4
. Connect the ground wire to the ground terminal. Use the diagram on the  
rear panel of the switch to identify terminals. Tighten the terminal to  
between 2.4 and 4.0 Nm (21.3 and 35.4 lbf in).  
. Connect the positive feed to the + (positive) terminal and the negative feed  
to the - (negative) terminal. Tighten the terminals to between 2.4 and  
4
.0Nm (21.3 and 35.4 lbf in).  
Note that the DC return input terminal must be connected as an Isolated  
DC return (DC-I).  
5
6
. Ensure that there are no exposed cable strands.  
. Replace the cover. You must replace the transparent plastic terminal cover  
before continuing.  
7
. Secure the supply cable to the rack framework or a similar object to ensure  
that connections are isolated from any force applied to the cable.  
1
3

Allied Telesis Switch X900-24XSの説明書の他にも、あなたがAllied Telesis Switch X900-24XSとその問題を解決するのに役立つヘルプパネルを提供しています。何か質問がある場合は、以下のフォームから送信することができます。他のユーザーがここを訪問し、あなたのAllied Telesis Switch X900-24XSに関する問題解決を支援してくれるかもしれません。また、あなたがたどり着いた解決方法についてもご共有することをお忘れなく。うまく解決できた場合はAllied Telesis Switch X900-24XSに関する問題とその解決法についてこちらにご記入ください - きっと数多くのユーザーに役立つことでしょう。