The RS969 family has 2 different power supply input connectors---Mini A-coded male connector or
M23 A-code male connector shown in Figure 2.2.1.1. The Mini power connector only has 4
terminals, so only one power supply source is allowed to connect to the RS969 with Mini power
connector; The M23 power connector has 5 terminal pins which means 2 power supply sources are
allowed to power the RS969 with M23 power connector.
The RS969 family supports dual redundant power supplies – “Power Supply 1 (PS1)”and “Power
Supply 2 (PS2)”. The connections for PS1, PS2 are shown in Table1 and 2.
Refer to
Table 1 and 2 for a description of each terminal and sections 2.3.2 through 2.3.4 for wiring
examples.
Terminal #
Description
Usage
PS1 Live / + is connected to the positive (+) terminal if the
PS1 Live / + power source is DC or to the (Live) terminal if the power
source is AC.
1
PS1 Neutral / - is connected to the negative (-) terminal if
PS1 Neutral / - the power source is DC or to the (Neutral) terminal if the
power source is AC.
Chassis Ground is connected to the Safety Ground
terminal for AC inputs or the equipment ground bus for DC
2
3
inputs. This terminal 3 is connected to chassis ground
internally in the RS969 family. There is also an additional
chassis ground screw and the chassis ground connects to
Chassis
Ground
both power supply surge grounds via a removable jumper
shown in Figure 2.2.1.2 .
PS2 Live / + is connected to the positive (+) terminal if the
power source is DC or to the (Live) terminal if the power
source is AC.
PS2 Neutral / - is connected to the negative (-) terminal if
PS2 Neutral / - the power source is DC or to the (Neutral) terminal if the
power source is AC.
4
5
PS2 Live / +
Table 1: RS969 Power terminal block connection description for M23 A-code male connector
1
0
2008 RuggedCom Inc. All rights reserved