User manual AquaPRO GPH550PRO

If you found this page, you probably have a problem and you need a user manual for the device AquaPRO GPH550PRO. Be sure to check that it is the user manual to exactly the device that you are looking for. In our database AquaPRO GPH550PRO it belongs to the category Water Pump. A user manualAquaPRO GPH550PRO is taken from the manufacturer, a AquaPRO company - it is an official document, so if you have any doubts as to its contents, please contact the manufacturer of the device AquaPRO GPH550PRO directly. You can view the user manualAquaPRO GPH550PRO directly online or save and store it on your computer.

Operating Instructions and Replacement Parts List  
GPH550PRO  
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.  
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or  
property damage! Retain instructions for future reference.  
Gas Powered  
Water Pump  
Need  
Assistance?  
Call Us First!  
1-877-278-2797  
the life of the pump and may be  
hazardous to the operator.  
Description  
!
WARNING  
8
. Personal Safety:  
The Aqua Pro pumps are general use  
centrifugal water pumps.  
Do not use to pump flammable  
or explosive fluids such as  
a. Wear safety glasses at all times  
when working with pumps.  
gasoline, fuel oil, kerosene, etc. Do not  
use in flammable and/or explosive  
atmospheres. Pump should only be used  
with liquids compatible with pump  
component materials. Failure to follow  
this warning can result in personal injury  
and/or property damage.  
Safety Guidelines  
b. Keep work area clean, uncluttered  
and properly lighted; replace all  
unused tools and equipment.  
This manual contains information that is  
very important to know and understand.  
This information is provided for SAFETY  
and to PREVENT EQUIPMENT PROBLEMS.  
To help recognize this information,  
observe the following symbols.  
c. Keep visitors at a safe distance from  
the work area.  
d. Make workshop child-proof with  
padlocks, master switches, and by  
removing starter keys.  
2
. Observe all safety precautions for the  
handling of the fuel.  
Danger indicates  
DANGER  
an imminently  
!
9. Always use a suction strainer with this  
pump to filter large material.  
!
WARNING  
hazardous situation which, if not avoided,  
will result in death or serious injury.  
Do not refuel a hot engine.  
Fuel spilled on a hot engine  
could result in a fire or explosion. Do not  
refuel a running engine.  
Warning indicates  
WARNING  
a potentially  
Installation  
!
hazardous situation which, if not avoided,  
could result in death or serious injury.  
This pump is designed to be self-  
priming when installed and operated as  
specified below.  
3. Pump should be located and should  
rest on a level solid foundation. Do  
not suspend pump by means of the  
discharge pipe.  
Caution indicates a  
CAUTION  
potentially  
!
1. The pump should be placed as close  
as possible to the liquid being  
pumped. A pump with 20 foot  
suction lift will not remove water as  
quickly as a pump with 5 foot  
suction lift (Figure 1).  
hazardous situation which, if not avoided,  
may result in minor or moderate injury.  
Be sure pump is on  
secure footing so it  
NOTICE  
doesn’t fall over.  
Notice indicates  
important  
information, that if not followed, may  
cause damage to equipment.  
NOTICE  
4. Do not use torches or apply excessive  
heat, fire or flames to this pump as an  
explosion may result.  
General Safety  
Information  
5
. Before working on the unit, insulate  
the wire from the spark plug,  
disconnect the spark plug wire and  
mount it on the grounding clip.  
20 Ft.  
Suction Lift  
1. Know the pump application,  
limitations, and potential hazards.  
Read these rules and the instructions  
carefully. Failure to follow them could  
cause serious bodily injury and/or  
property damage.  
Complete pump  
and piping system  
MUST be protected against below  
freezing temperature. Failure to do so  
could cause serious damage and voids  
the warranty.  
NOTICE  
5
Suction  
Lift  
Ft.  
!
DANGER  
6
. Do not run pump dry. Water is  
required to lubricate the shaft  
seal.  
Figure 1  
Never run engine in an  
enclosed area. Exhaust gases  
contain deadly poisonous carbon  
monoxide, which has no odor or taste.  
2. Suction hose and fitting must be  
7. Pumping chemicals or corrosive  
liquids with this pump may shorten  
airtight.  
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.  
22600-013 03/06  
3

In addition to the user manual AquaPRO GPH550PRO, we also provide a support panel to help you solve your problems with AquaPRO GPH550PRO. If you have any questions, you can ask them in the form below. Other users viewing this website will have the opportunity to help you solve your probem with AquaPRO GPH550PRO. Remember that you can also share the solution. If you solved the problem yourself, please write the solution to the problem with AquaPRO GPH550PRO - you will surely help many users by doing so.

Have you got problems with your device? Ask a question - our users can help you

No one has added a comment for this device/ user manual.