User manual American Standard TOWNSQUARE 2555.602

If you found this page, you probably have a problem and you need a user manual for the device American Standard TOWNSQUARE 2555.602. Be sure to check that it is the user manual to exactly the device that you are looking for. In our database American Standard TOWNSQUARE 2555.602 it belongs to the category Plumbing Product. A user manualAmerican Standard TOWNSQUARE 2555.602 is taken from the manufacturer, a American Standard company - it is an official document, so if you have any doubts as to its contents, please contact the manufacturer of the device American Standard TOWNSQUARE 2555.602 directly. You can view the user manualAmerican Standard TOWNSQUARE 2555.602 directly online or save and store it on your computer.

InInsstrtaulclatitoionns  
2555.602  
TOWNSQUARE  
PRESSURE BALANCING BATH AND  
SHOWER-Built-in Diverter for TUB FILLER  
Thank you for selecting American-Standard...the benchmark  
of fine quality for over 100 years.  
To ensure that your installation proceeds smoothly--please  
read these instructions carefully before you begin.  
Certified to comply with ANSI A112.18.1  
M968789 Rev. 1.5  
Required Tools  
ROUGHING-IN DIMENSIONS  
To assure proper positioning in relation to wall, note  
roughing-in dimensions.  
1
-5/8" TO 3-1/4"  
FINISHED WALL  
1
Phillips Screwdriver  
1
/2" I.P.S.  
2
" REF.  
OPTIONAL TO  
Flat Blade Screwdriver  
FINISHED FLOOR  
USUALLY BETWEEN  
6
5'' AND 78''  
8
" REF.  
OUTLETS 1/2" NPT  
7
4" FOR  
HEAD CLEARANCE  
SHW  
"SEE ILLUSTRATION"  
Plumbers' Putty or Caulking  
5
-5/8"  
7
-1/2"  
TUB  
1
8"  
OPTIONAL  
1
-3/4"  
7
-1/4" REF.  
Channel Locks  
INLETS  
1/2" NPT  
5-5/8"  
1
/2" COPPER  
THREADED INLETS (STOPS)  
4
"
TOP OF  
TUB RIM  
1-3/4" REF.  
Adjustable Wrench  
BOTTOM OF  
TUB  
Turn off water at main supply.  
ROUGHING-IN  
CAUTION  
1
NOTE When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When finished soldering,  
flush valve body, replace cartridges, check stops (if present) and plaster guard to continue installation. Use thread  
sealant or Teflon tape on threaded connections.  
5
7
See Roughing-in diagram before starting.  
Connections are:  
If the valve is installed on a fiberglass  
or other thin wall application, the  
1
2
PLASTER GUARD (4) can be used as a support.  
1/2" female NPT for threaded inlets  
COLD  
Cut a 4" dia. hole in the shower stall.  
Drill two additional 1" holes to allow access  
to the stops.  
Remove PLASTER GUARD (4), rotate 180˚  
so that indicated screw holes fit MANIFOLD (2).  
Push CAP on valve, place ESCUTCHEON on and  
attach with screws.  
4
Connect RISER PIPE (1) to MANIFOLD (2)  
top outlet marked "SHR".  
Connect TUB FILLER PIPE (3) at bottom  
outlet marked "TUB".  
For proper positioning the finished wall  
must be within side wall of PLASTER  
GUARD (4).  
HOT  
3
Connect hot and cold water supplies.  
Cap off shower pipe (5) and tub filler pipe (6).  
For support, use pipe BRACES (7) secured to wooden braces.  
6
With valve turned off, turn on water supplies. Check for leaks.  

In addition to the user manual American Standard TOWNSQUARE 2555.602, we also provide a support panel to help you solve your problems with American Standard TOWNSQUARE 2555.602. If you have any questions, you can ask them in the form below. Other users viewing this website will have the opportunity to help you solve your probem with American Standard TOWNSQUARE 2555.602. Remember that you can also share the solution. If you solved the problem yourself, please write the solution to the problem with American Standard TOWNSQUARE 2555.602 - you will surely help many users by doing so.