User manual American Standard SYMPHONY 4501

If you found this page, you probably have a problem and you need a user manual for the device American Standard SYMPHONY 4501. Be sure to check that it is the user manual to exactly the device that you are looking for. In our database American Standard SYMPHONY 4501 it belongs to the category Plumbing Product. A user manualAmerican Standard SYMPHONY 4501 is taken from the manufacturer, a American Standard company - it is an official document, so if you have any doubts as to its contents, please contact the manufacturer of the device American Standard SYMPHONY 4501 directly. You can view the user manualAmerican Standard SYMPHONY 4501 directly online or save and store it on your computer.

InInssttraulclatitoionns  
SYMPHONY  
PRESSURE BALANCING BATH  
AND SHOWER TRIM KITS  
4
501  
4
501S  
Thank you for selecting American-Standard...the benchmark  
of fine quality for over 100 years.  
To ensure that your installation proceeds smoothly--please  
read these instructions carefully before you begin.  
Certified to comply with ANSI A112.18.1  
M968805 REV. 1.4  
ROUGHING-IN DIMENSIONS  
To assure proper positioning in relation  
to wall, note roughing-in dimensions.  
1
-5/8" TO 3-1/4"  
FINISHED WALL  
1
/2" NPT  
3
-5/8" REF.  
OPTIONAL TO FINISHED  
FLOOR USUALLY  
BETWEEN 65'' AND 80''  
INLETS 3-3/8"  
SHR. 1/2" NPT  
5
-1/2" REF.  
"
SEE ILLUSTRATION "  
3
-3/8"  
7
4" FOR HEAD  
INLETS 1/2" NPT  
CLEARANCE  
6
-3/4"  
TUB PORT 1/2" NPT  
'
18" OPTIONAL  
3
-5/8"  
THREADED INLETS  
1
/2" NPT''  
5
-1/8" REF.  
4
"
TOP OF TUB RIM  
BOTTOM OF TUB  
Turn off water at main supply.  
ROUGHING-IN  
CAUTION  
1
5
NOTE When soldering, remove PLASTER GUARD, CARTRIDGES and CHECK STOPS (IF PRESENT). When finished soldering,  
flush valve body, replace cartridges, check stops (if present) and plaster guard to continue installation. Use thread  
sealant or Teflon tape on threaded connections.  
7
See Roughing-in diagram before starting.  
Connections are:  
If the valve is installed on a fiberglass  
or other thin wall application, the  
PLASTER GUARD (4) can be used as a support.  
Cut a 4" dia. hole in the shower stall.  
Drill two additional 1" holes to allow access  
to the stops.  
1
1/2" female NPT for threaded inlets  
COLD  
2
4
Connect RISER PIPE (1) to MANIFOLD (2)  
top outlet marked "SHR".  
HOT  
Remove PLASTER GUARD (4), rotate 90˚  
so that indicated screw holes fit MANIFOLD (2).  
Push CAP on valve, place ESCUTCHEON on and  
attach with screws.  
Connect TUB FILLER PIPE (3) at bottom  
outlet marked "TUB".  
3
For proper positioning the finished wall  
must be within side wall of PLASTER  
GUARD (4).  
Connect hot and cold water supplies.  
6
Cap off shower pipe (5) and tub filler pipe (6).  
For support, use pipe BRACES (7) secured to wooden braces.  
With valve turned off, turn on water supplies. Check for leaks.  

In addition to the user manual American Standard SYMPHONY 4501, we also provide a support panel to help you solve your problems with American Standard SYMPHONY 4501. If you have any questions, you can ask them in the form below. Other users viewing this website will have the opportunity to help you solve your probem with American Standard SYMPHONY 4501. Remember that you can also share the solution. If you solved the problem yourself, please write the solution to the problem with American Standard SYMPHONY 4501 - you will surely help many users by doing so.