Operating Manual - NE Multi Channel Power Amplifiers
4
) Pluggable Input DSP Tools - Six boxes are available for custom configuration of pluggable DSP processing
blocks. Available DSP blocks include Dynamics controls, Gain functions, Graphic and Parametric EQ, Cross
over functions, Delay, Metering, and a signal generator.
5
6
) Input/Output Matrix Router - Any input can be routed to any or all outputs. Click and drag from the input to
output to assign routing. To delete a route, right click on the routing line and delete.
) Output Mixer - For a given amplifier output channel, all inputs that have been routed in the matrix router are
mixed together here.
7
8
9
1
) Pluggable Output DSP Tools - Output DSP tools are the same as those available to the inputs.
) Output Mute Button - Mutes the output.
) Output Channel Name - The user can name each output channel.
0) Output Channel Number - Right click on this to bring up Clear, Copy, Link, and Sub Preset functions for that
output channel.
6
. SPECIFICATIONS
General Power Amplifier Specifications
Power Output
Stereo Mode, All Channels Driven
8
4
ohms, 20Hz-20kHz 1%THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150W
ohms, 20Hz-20kHz 1%THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250W
Bridge Mode
8
2
ohms, 20Hz-20kHz 1%THD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500W
5, 70, 100 Volt models, 20Hz-20kHz 1%THD, per channel . . . . . . . . . . . . . . . . . . . . . . 250W
Signal to Noise (20Hz-20KHz, unweighted) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >98dB
Power Requirements (1/8 Power Pink Noise @4 Ohm): . . . . . . . . . . . . . . . . . . . . . . . . . . 360W - 8Ch, 200W - 4Ch
Distortion (SMPTE, typical) - 8 ohm load, 10dB below rated power: . . . . . . . . . . . . . . . <0.5%
Distortion (THD-N, typical) - 8 ohm load, 10dB below rated power, 20Hz-20kHz: . . . . <0.5%
Frequency Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Hz-20kHz, +/-1dB
Damping Factor (8 ohm load, <1kHz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >250
Input Impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20K Ohm, balanced
Maximum Input Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +21dB
Cooling . . . . . . . . . . . . . . temperature dependent speed-controlled axial fan
Control Network . . . . . . . onboard, compatible with standard 100MB Ethernet hardware
Front Panel Indicators . . per channel: Clip/Mute, -6dB, -12dB, -18dB, Temp, Current, Bridge (per pair)
overall: Power, Standby, Protect, Power Switch Disable, Comm
Control Surface and Amp LEDs: Level meters are dB below RATED output
Attenuators:
per channel: front panel, software, offset link group, and remote
Input Connections . . . . . Euroblock
Output Connections . . . . Euroblock
Amplifier Protection
inrush current limitation, temperature monitoring, output over-current protection, mains fuses
Power Cable Connector 15A Edison
Dimensions . . . . . . . . . . . 19”W x 3.5”H x 15.5”D (483 x 89 x 394mm)
Weight . . . . . . . . . . . . . . . 21 lbs (9.53kg)
Environmental: . . . . . . . . 40-120 deg. F, (4-49 deg, C) noncondensing