If you found this page, you probably have a problem and you need a user manual for the device Extron electronic WM EC F. Be sure to check that it is the user manual to exactly the device that you are looking for. In our database Extron electronic WM EC F it belongs to the category Stereo Amplifier. A user manualExtron electronic WM EC F is taken from the manufacturer, a Extron electronic company - it is an official document, so if you have any doubts as to its contents, please contact the manufacturer of the device Extron electronic WM EC F directly. You can view the user manualExtron electronic WM EC F directly online or save and store it on your computer.

Controls and Installation, cont’d  
Balanced audio  
To attach the distribution amplifier to a balanced audio system,  
do the following:  
Adapter Plate  
1.  
Attach the audio cable to a balanced speaker input  
connector (tip, ring, and sleeve).  
AUTOPOWER  
AUDIO  
Tip (L)  
1
00%  
UNITY  
INPUT  
Ring (R)  
5
0%  
GAIN/PEAKING  
BUFFERED  
ID PIN  
4
LOCAL MONITOR  
ID PIN 11  
#
4-40 Nut w/ Captive  
Washer  
Sleeve (  
)
P/2 DA2 WM F AAP  
2.  
Attach the audio cable to the audio cable connector (Extron  
part number 10-319-10). Fasten the captive screws inside  
the audio cable connector as shown below.  
(
up to 4 plates)  
P/2  
D
A2 WM  
F AAP  
Tip  
Ring  
Left  
Sleeve(s)  
P/2 DA2 WM F AAP EC  
Tip  
Right  
AUTO POWER  
Ring  
GAIN/  
PEAKING  
ID PINS  
P/2 DA2 WM F AAP EC  
(up to 3 plates)  
Balanced Output  
3.  
Slide the audio cable connector into the audio output  
connector on the distribution amplifier.  
Installingadapterplates  
Installing architectural adapter plates  
The P/2 DA2 WM F AAP may have up to four optional adapter  
plates and the P/2 DA2 WM F AAP EC can have up to three  
adapter plates. The adapter plates provide a convenient method  
of adding various connectors for specific audio and video  
requirements. The adapter plates must be ordered separately  
and must be attached to the faceplate and cabled before  
attaching the WM F AAP model to the wall mount bracket or  
the EC F AAP model to the Euro Channel.  
2.  
Attach the output cables to the back side of the adapter  
plate. Some adapter plates may require that conductors be  
soldered to the connectors. Attach foil and braided shields  
to ground connections.  
1.  
Insert the adapter plate captive screws through the front  
faceplate holes. Secure the adapter plate using the  
supplied washers and nuts.  
2
-12  
P/2 DA2 WM/EC/D/AAP Series • Controls and Installation  
P/2 DA2 WM/EC/D/AAP Series • Controls and Installation  
2-13  

In addition to the user manual Extron electronic WM EC F, we also provide a support panel to help you solve your problems with Extron electronic WM EC F. If you have any questions, you can ask them in the form below. Other users viewing this website will have the opportunity to help you solve your probem with Extron electronic WM EC F. Remember that you can also share the solution. If you solved the problem yourself, please write the solution to the problem with Extron electronic WM EC F - you will surely help many users by doing so.