User manual Linear AVP12000

If you found this page, you probably have a problem and you need a user manual for the device Linear AVP12000. Be sure to check that it is the user manual to exactly the device that you are looking for. In our database Linear AVP12000 it belongs to the category Vacuum Cleaner. A user manualLinear AVP12000 is taken from the manufacturer, a Linear company - it is an official document, so if you have any doubts as to its contents, please contact the manufacturer of the device Linear AVP12000 directly. You can view the user manualLinear AVP12000 directly online or save and store it on your computer.

PRINTER’S INSTRUCTIONS:  
INSTR,H.O. GUIDE,AIRVAC; LINEAR P/N: 227004 B; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 11.000” x 17.000”; FOLDING: 1-FOLD VERTICAL, 1-FOLD HORIZONTAL, FINISH 8.500” X 5.500” WITH LOGO SHOWING; SCALE: 1-1  
CENTRAL VACUUM MODELS  
AVP3000, AVP7500, AVP12000, AVP24000  
AVR3000, AVR7500, AVR12000, AVR24000  
3
Bagged Platinum Series  
Emptying a Platinum Series Central Vacuum Power Unit  
REMOVING THE DEBRIS BUCKET  
The debris bucket is the removable lower section of  
the power unit. The Platinum Series central vacuums  
contain a Model VMP600 slide-gate collar dust bag that  
is installed inside the debris bucket. The debris level in  
the dust bag is indicated by the front panel display of the  
vacuum. The dust bag should be replaced when the red  
bars of the bag level indicator light (bag full). Regular dust  
bag replacement will enhance performance and conform  
to the terms of the product warranty. The dust bag inside  
the debris bucket should be replaced five to six times a  
year under normal use.  
SWINGTHE TWO  
BUCKET SLIDE  
LATCHESDOWN  
HOMEOWNER’S INSTRUCTIONS  
For Platinum and Red Series AirVac Units  
(
for Household Use Only)  
IMPORTANT SAFETY NOTES  
Please read the instructions carefully! Through many years of continuous use -- and through quality tests that are  
ongoing at our factory -- AirVac central vacuums, attachments and accessories have built a remarkable record  
for cleaning effectiveness and safety. However, there are potential hazards that could occur if the system is not  
installed and operated correctly and safely. READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE.  
REMOVE DEBRIS  
BUCKET FROM  
BUCKET SLIDE  
LATCHES  
The Platinum Series vacuums contain a self-cleaning  
inverted cloth filter. When the power unit is running,  
the cloth filter is pulled upward inside the vacuum body.  
When the power unit is turned off, the weighted center of  
the filter causes it to drop, depositing dirt and dust past  
the dust cone and into the debris bucket. It is normal to  
see some accumulation of dirt on the filter. The inverted  
cloth filter should not be removed for any reason  
except to replace it if it becomes damaged or torn.  
THE FOLLOWING FORMATS ARE USED FOR SAFETY NOTES IN THESE INSTRUCTIONS.  
REMOVING THE DUST BAG  
CAUTION  
WARNING  
This type of warning note is used to indicate This type of warning note is used to indicate  
the possibility of damage to the vacuum power possible fire or electrical shock hazards that  
REMOVE DUST  
BAGFROM  
BUCKET  
unit or vacuum duct system.  
may cause serious injuries or death.  
IMPORTANT SAFETY INSTRUCTIONS  
To replace the dust bag, follow these easy steps:  
1
Make sure the power unit is disconnected from the  
electrical wall outlet.  
PULL SLIDE GATE  
ON BAGCOLLAR  
TO CLOSE THE BAG  
WARNING  
READTOthisRmEDanUuaCl EbeTfoHreEasRsIeSmKblinOgForFuIsRinEg, ELE1C1TDROICNAOTLaSlloHwOtCheKs,ysOteRmItNo bJeUuRseYd:as a toy.  
2
Swing the two bucket slide latches down to lower the  
debris bucket.  
DISPOSE OF BAG  
IN REFUSE CONTAINER  
1
2
3
4
your vacuum cleaner.  
Close attention is necessary when used near  
children.  
3
4
Remove the debris bucket from the slide latch hangers.  
USE your vacuum only as directed in this manual.  
Use only recommended attachments.  
Remove the dust bag from the debris bucket and pull  
on the bag’s slide-gate to seal the bag.  
INSTALLING THE DUST BAG  
12 DO NOT handle the plug or electric power head  
with wet hands.  
PLACE THE BAGINTO THE  
DEBRISBUCKET AND  
EXPAND THE BAGAGAINST  
THE DEBRISBUCKET SIDES  
5
6
Dispose of the dust bag in a refuse container.  
KEEP hair, loose clothing, fingers and all parts of  
the body away from openings and moving parts.  
EXPAND THE DUST  
Use your hand to expand the bag of a new VMP600 BAGBEFORE PLACING  
13 DO NOT operate the vacuum with a punctured  
hose. The hose contains electrical wires. If the  
hose is cut or worn, it should be replaced  
immediately. Avoid vacuuming sharp objects.  
IT INTO THE DEBRISBUCKET  
dust bag and place it into the debris bucket.  
DISCONNECT electric power head before  
servicing or cleaning the brush area. Failure to do  
so could result in electric shock or sudden start-  
up of the brush.  
PLACE BAG'S  
SLIDE-GATE  
HERE  
7
Reach into the dust bag again and expand the bag  
against the sides of the debris bucket.  
8
9
Reattach the debris bucket on to the slide latch hangers.  
14 DO NOT put any objects into openings. Do not  
use with all openings blocked; keep free of dust,  
lint, hair, and anything that may reduce air flow.  
Swing the two bucket slide latches up to raise and  
seat the debris bucket.  
5
ALWAYS turn electric power head off before  
connecting or disconnecting the hose or power  
nozzle.  
10 Reconnect the power unit to the electrical wall outlet.  
15 DO NOT use the vacuum to pick up hard, sharp  
objects. They may damage the vacuum.  
11 Press the RESET button for seven seconds to reset  
the bag indicator.  
SLIDE-GATE COLLARBAG  
6
7
USE extra care when cleaning on stairs.  
DO NOT use outdoors, on wet surfaces, or to  
pickup liquids of any kind. Electric shock could  
occur.  
16 DO NOT use the vacuum to pick up flammable or  
combustible liquids (gasoline, cleaning fluids,  
perfumes, etc.) or use in areas where they may  
be present. Fumes from these substances can  
create a fire hazard or explosion.  
4 Emptying a Red Series Central Vacuum Power Unit  
Bagless Red Series  
The debris bucket is the removable lower section of  
the power unit. The debris bucket is semi-transparent,  
the dirt level can be seen through its sides. The debris  
bucket in the Red Series central vacuum must be  
checked periodically and emptied when it becomes 3/4  
full. Regular emptying will enhance performance and  
conform to the terms of the product warranty. Dirt and  
debris are deposited in the debris bucket and it should be  
emptied five to six times a year under normal use.  
8
9
DO NOT unplug by pulling on the cord.To unplug,  
pull the plug, not the cord.  
REMOVING THE DEBRIS BUCKET  
SWINGTHE TWO  
BUCKET SLIDE  
LATCHESDOWN  
1
7 DO NOT use without the dust bag in place  
DO NOT operate the system if the power cord,  
hose, or power nozzle is damaged or the  
equipment has been left outdoors. Send the unit  
to a qualified service repair center.  
(Platinum Series only).  
18 DO NOT use system to clean ashes from a  
fireplace, as smoldering embers can burn for  
days after the fire is out.  
1
0 DO NOT pull or carry the unit by the cord, or pull  
around sharp edges or corners. Do not run the  
power nozzle over the cord. Keep the cord away  
from heated surfaces.  
SAVE THESE  
INSTRUCTIONS  
The Red Series bagless vacuums contain a self-cleaning  
inverted cloth filter. When the power unit is running, the  
cloth filter is pulled upward inside the vacuum body.  
When the power unit is turned off, the weighted center  
of the filter causes it to drop, depositing dirt and dust into  
the debris bucket. It is normal to see some accumulation  
of dirt on the filter. The inverted cloth filter should not  
be removed for any reason except to replace it if it  
becomes damaged or torn.  
REMOVE DEBRIS  
BUCKET FROM  
BUCKET SLIDE  
LATCHES  
1
Central Vacuum Accessories  
REPLACING THE DEBRIS BUCKET  
Many accessory packages and tool kits are available for AirVac central vacuums. Refer to the packages below and  
contact your local AirVac central vacuum dealer for these and additional central vacuum components.  
VM1200S Air-driven Turbo System Package  
Non-electric system for maximum economy.  
VMTKD Deluxe Tool Kit  
Features high-quality horsehair bristles.  
To empty the debris bucket, follow these easy steps:  
Low-voltage crush-proof swivel hose with on/off Adjustable carpet/floor tool  
switch  
Floor/wall tool  
Crevice tool  
1
2
3
Make sure the power unit is disconnected from the  
electrical wall outlet.  
BUCKET  
SLIDE  
LATCH  
Air-driven 12” turbo carpet brush  
Deluxe horsehair tools  
Telescopic vacuum accessory wand  
Hose rack and cloth caddy bag for tools  
Dusting brush  
Upholstery tool with brush  
Button-lock wand  
Swing the two bucket slide latches down to lower the  
debris bucket.  
SWINGTHE TWO  
BUCKET SLIDE  
LATCHESUP  
HANGDEBRIS  
BUCKET ON BUCKET  
SLIDE LATCHES  
Remove the debris bucket from the slide latch hangers  
and empty the bucket into a refuse container.  
Telescopic vacuum accessory wand  
VM2200DS Standard Electric Package  
Electric system with separate electric cord.  
VMGAR Deluxe Garage/Car Tool Kit  
Features high-quality horsehair bristles.  
4
5
Reattach the debris bucket on to the slide latch hangers.  
Swing the two bucket slide latches up to raise and  
seat the debris bucket.  
Crush-proof swivel hose with on/off switch  
Deluxe 14” self-adjusting electric carpet brush 30-foot crushproof hose and rack  
with headlight  
Deluxe horsehair tools  
Telescopic vacuum accessory wand  
Hose rack and cloth caddy bag for tools  
Upholstery tool with brush  
Floor/wall tool  
Telescopic vacuum accessory wand  
Adjustable carpet/floor tool  
6
Reconnect the power unit to the electrical wall outlet.  
5
IF THE MOTOR FAILS TO OPERATE  
Troubleshooting  
CAUTION  
NO USER SERVICEABLE PARTS INSIDE.  
DO NOT LUBRICATE THE MOTOR.  
Dusting brush  
On-board tool caddy  
Crevice tool  
VM4200DS Deluxe SuperSystem Package  
Electric system with built-in cord.  
1
2
3
Be sure the power unit is plugged into a working AC outlet.  
Push circuit breaker reset button on the power unit.  
Deluxe direct-connect crush-proof swivel hose  
with three-position switch  
Deluxe 14” self-adjusting electric carpet brush  
with headlight  
Deluxe horsehair tools  
Check the panel circuit breaker that connects the power unit. If the breaker has tripped, reset it. If the breaker  
trips again, call your AirVac dealer for service.  
Also visit www.purelypowerful.com for more  
AirVac Central Vacuum accessories.  
AFTER CHANGING OF THE BAG (PLATINUM SERIES ONLY)  
1 Push down the RESET button for seven seconds to reset the bag indicator.  
Telescopic vacuum accessory wand  
Hose rack and cloth caddy bag for tools  
IN CASE OF LOW VACUUM POWER  
1
2
3
4
5
6
Be sure that the inlet plug is inserted into the unused power unit intake port.  
Check that all wall valves are closed.  
2
Platinum Series Service Indicators  
Bag Indicator  
The Platinum Series central vacuums have an indicator on the control panel to display the approximate debris level  
of the vacuum’s replaceable dust bag. The green, yellow, orange, and red indicators will light, showing the bag  
debris level. The bag indicator displays the dust bag level whether the vacuum power is on or off.  
Check that all gaskets on wall valves are sealed.  
Check to see if debris bucket or bag (Platinum Series only) needs emptying.  
Check for obstructions in the hose, tools, or vacuum lines.  
Check for any ruptures or breaks in the vacuum duct system.  
If you encounter any problems with your equipment, verify the operation against the information contained in these  
instructions. If, after checking your system you are unable to determine the cause of the problem, contact your local  
AirVac dealer for assistance or call our Technical Services department at (800) 421-1587. Be sure to have the exact  
model number, serial number, and the nature of the problem ready. If possible, CALL FROM THE SITE. We cannot  
effectively troubleshoot your system if you are not calling from the location where the equipment is installed or used.  
NOTE: The debris level indicator light is meant to provide an approximation of the actual level in the dust bag. In a  
heavy use environment, (i.e. pet hair or new carpet fuzz) the bag may fill before the indicator reads full.  
Service Indicator  
The Platinum Series central vacuums have an indicator on the control panel to display the status of the vacuum’s  
motor and when the motor will require service.The service indicator displays the motor status whether the vacuum  
power is on or off.  
6 Limited Warranty  
Linear LLC warrants AirVac Platinum Series power units to be free of defects for THIS LIMITEDWARRANTY IS IN LIEU OF ANY OTHERWARRANTIES, EXPRESS  
10 years, and AirVac Red Series power units to be free of defects for 5 years. The OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY  
Professional Installation By:  
warranty period begins from either (1) the date of “first user” purchase of this product OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, AND OF ANY  
or (2) the first close of escrow date on a residence in which this new product was OTHER OBLIGATIONS OR LIABILITY ON THE SELLER’S PART. THIS LIMITED  
originally installed. This warranty extends to the original user of the product and to WARRANTY DOES NOT COVER DAMAGE CAUSED BY ACTS OF GOD,  
each subsequent owner of the product during the term of this warranty. Linear LLC IMPROPER INSTALLATION, NORMAL SYSTEM WEAR AND TEAR AS DEFINED  
will repair or replace, at its option, parts and materials at no charge. Parts supplied BY THE MANUFACTURER, THE VIOLATION OF APPLICABLE BUILDING OR  
PLATINUM SERIES SERVICE INDICATOR  
INDICATOR COLOR  
MOTOR CONDITION  
NORMAL, NO ACTION  
REQUIRED  
under this warranty may be new or rebuilt at the option of Linear LLC.  
ELECTRICAL CODES, OR THE USE OF NON-AIRVAC WIRE, CABLE, OR  
GREEN  
If, during the limited warranty period, it appears as though this product contains a WALL HOUSINGS. THIS LIMITED WARRANTY APPLIES ONLY TO PRODUCTS  
defect which is covered by this limited warranty, call our toll free service number INSTALLED IN A PRIVATE RESIDENCE.  
MOTOR SERVICE WILL  
BE REQUIRED SOON  
before dismantling the product (1-800-421-1587). Remember to attain a Return UNDER NO CIRCUMSTANCES SHALL THE SELLER BE LIABLE FOR  
Product Authorization number (RPA) before returning any product to Linear CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN  
LLC. Send this product freight pre-paid and insured to our service center for CONNECTION WITH USE, OR INABILITY TO USE THIS PRODUCT. IN NO EVENT  
warranty repair. You will be advised on shipping instructions when you call the toll SHALL SELLER’S LIABILITY, FOR BREACH OF WARRANTY, BREACH OF  
free service number. Linear LLC will return the repaired product freight pre-paid CONTRACT, NEGLIGENCE, OR STRICT LIABILITY, EXCEED THE COST OF THE  
within the U.S.A. The installing dealer or distributor may assist you, at your choice PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR  
and expense, with returning product for repair. Please include a brief description of US ANY OTHER LIABILITY IN CONNECTIONWITHTHE SALE OFTHIS PRODUCT.  
the problem and a dated proof-of-purchase receipt with any product that is returned Some states do not allow the exclusion or limitation of consequential, incidental or  
FLASHING GREEN  
FLASHING RED  
RED  
HAVE MOTOR SERVICED NOW  
Manufactured By:  
HAVE MOTOR SERVICED  
IMMEDIATELY  
(760) 438-7000  
USA & Canada (800) 421-1587 & (800) 392-0123  
Toll Free FAX (800) 468-1340  
for warranty repair. ANY PRODUCT RETURNED WITHOUT A RETURN PRODUCT  
special damages, so the above limitation or exclusion may not apply to you. This  
AUTHORIZATION NUMBER WILL BE REFUSED.  
www.linearcorp.com  
limited warranty gives you specific legal rights, and you may also have other rights  
which vary from state to state.  
Copyright © 2006 Linear LLC  
227004 B  

In addition to the user manual Linear AVP12000, we also provide a support panel to help you solve your problems with Linear AVP12000. If you have any questions, you can ask them in the form below. Other users viewing this website will have the opportunity to help you solve your probem with Linear AVP12000. Remember that you can also share the solution. If you solved the problem yourself, please write the solution to the problem with Linear AVP12000 - you will surely help many users by doing so.

Have you got problems with your device? Ask a question - our users can help you