Si has encontrado esta página, seguramente tienes un problema y necesitas el manual de instrucciones para el dispositivo Quantum Instruments MS3580. Recuerda comprobar si es el manual exacto para el dispositivo que buscas. En nuestra base Quantum Instruments MS3580 pertenece a la categoría Escáner. El manual Quantum Instruments MS3580 es del fabricante, la empresa Quantum Instruments - es un documento oficial y si tienes alguna duda acerca de su contenido, contacta directamente con el fabricante del dispositivo Quantum Instruments MS3580. El manual Quantum Instruments MS3580 se puede ver directamente online o guardar y almacenar en tu ordenador.

INSTALLATION  
Keyboard Wedge  
1. Turn off the host device.  
2
. Plug the male 10-pin RJ45 end of the  
PowerLink cable into the 10-pin  
socket on the MS3580.  
3. Disconnect the keyboard from the  
host device.  
4. Connect the “Y” end of the PowerLink  
cable to the keyboard and the  
keyboard port on the host PC. If  
necessary use the male/female  
adapter cable supplied with the  
scanner for proper connections.  
5. Plug the external power supply into the  
power jack on the PowerLink cable.  
Check the AC input requirements  
of the power supply to make sure  
the voltage matches the AC  
outlet. The outlet must be  
located near the equipment and  
be easily accessible.  
Figure 10.  
6
. Connect AC power to the transformer.  
. Turn on the host device.  
7
When the scanner first receives power, the blue LED will turn on; the  
scanner will simultaneously emit a beep and flash the white LED.  
Powering the MS3580 directly from the host device can sometimes  
cause interference with the operation of the scanner or the computer.  
Not all computers supply the same current through the keyboard port.  
For this reason, Metrologic recommends using an external power  
supply. For additional information contact a Metrologic customer  
service representative.  
Caution:  
To maintain compliance with applicable standards, all circuits connected to the scanner  
must meet the requirements for SELV (Safety Extra Low Voltage) according to EN/IEC  
60950.  
To maintain compliance with standard CSA C22.2 No. 60950/UL 60950 and norm  
EN/IEC 60950, the power source should meet applicable performance requirements for  
a limited power source.  
10  

Además del manual Quantum Instruments MS3580 facilitamos un panel de soporte que te ayudará a solucionar tus problemas con Quantum Instruments MS3580. Si tienes alguna pregunta, puedes escribirla en el formulario más abajo. Otros usuarios que entran aquí tendrán la oportunidad de ayudarte en la solución de tu problema con Quantum Instruments MS3580. Recuerda que también puedes compartir tu solución. Si has logrado solucionar el problema, por favor escribe aquí la descripción y la solución del problema con Quantum Instruments MS3580 - seguro que ayudarás a muchos usuarios.