Si has encontrado esta página, seguramente tienes un problema y necesitas el manual de instrucciones para el dispositivo Allied Telesis Switch X900-24XS. Recuerda comprobar si es el manual exacto para el dispositivo que buscas. En nuestra base Allied Telesis Switch X900-24XS pertenece a la categoría Interruptor. El manual Allied Telesis Switch X900-24XS es del fabricante, la empresa Allied Telesis - es un documento oficial y si tienes alguna duda acerca de su contenido, contacta directamente con el fabricante del dispositivo Allied Telesis Switch X900-24XS. El manual Allied Telesis Switch X900-24XS se puede ver directamente online o guardar y almacenar en tu ordenador.

x900 Series Switch and SwitchBlade® x908  
1
2
3
4
. Plug the AC power cord that is provided into the power inlet on the PSU.  
. Connect the power cord to the main power source.  
. On the AT-PWR05, set the Run/Standby switch to Run.  
. Check that the PSU LED on the front panel of the switch is lit green. If the  
LED does not light, refer to the Hardware Reference for troubleshooting  
information.  
Connecting a DC power supply  
Follow these instructions to connect an AT-PWR01 or an AT-PWR05 DC PSU  
to a DC power supply. Only trained and qualified personnel should connect a  
DC power supply.  
For centralised DC power connection, the switch should be installed in  
restricted access areas only, such as dedicated equipment rooms or  
equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of  
the National Electrical Code, ANSI/NFPA 70.  
Warning In order to avoid damaging the PSU, make sure that the PSU terminals  
are wired to the correct polarity.  
Warning When x900-24 units are connected with VCS stacking cables (XEM-  
STK-CBL) ensure that all the PSUs are appropriately grounded. This is to avoid  
large circulating ground currents that could damage the stacking cables. To  
achieve this ensure that:  
AT-PWR01 DC is grounded at the GND terminal. In order to avoid  
large circulating ground currents, the wires of each grounding cable  
must be 18AWG or thicker.  
All grounding points are at the same ground level. That is, all power  
connectors share a common power distribution unit.  
Warning When mounting one or two AT-PWR01 DC PSUs to a grounded rack,  
ensure that the ground level of the rack and the DC power connector are the  
same.  
Warning For x900-24 models, when using an AT-PWR01 AC power supply and  
an AT-PWR01 DC power supply in the same switch, then the ground-terminal of  
the DC power connector must be connected to the same ground as the AC  
ground pin of the AC power connector.  
If this is not possible, then you must ground the AT-PWR01 AC only, and leave  
the AT-PWR01 DC power connector ungrounded. In this case, as a safety  
precaution, ensure that the rack is also grounded.  
1
2

Además del manual Allied Telesis Switch X900-24XS facilitamos un panel de soporte que te ayudará a solucionar tus problemas con Allied Telesis Switch X900-24XS. Si tienes alguna pregunta, puedes escribirla en el formulario más abajo. Otros usuarios que entran aquí tendrán la oportunidad de ayudarte en la solución de tu problema con Allied Telesis Switch X900-24XS. Recuerda que también puedes compartir tu solución. Si has logrado solucionar el problema, por favor escribe aquí la descripción y la solución del problema con Allied Telesis Switch X900-24XS - seguro que ayudarás a muchos usuarios.