Si has encontrado esta página, seguramente tienes un problema y necesitas el manual de instrucciones para el dispositivo Allied Telesis Switch X900-24XS. Recuerda comprobar si es el manual exacto para el dispositivo que buscas. En nuestra base Allied Telesis Switch X900-24XS pertenece a la categoría Interruptor. El manual Allied Telesis Switch X900-24XS es del fabricante, la empresa Allied Telesis - es un documento oficial y si tienes alguna duda acerca de su contenido, contacta directamente con el fabricante del dispositivo Allied Telesis Switch X900-24XS. El manual Allied Telesis Switch X900-24XS se puede ver directamente online o guardar y almacenar en tu ordenador.

x900 Series Switch and SwitchBlade® x908  
Selecting a Site  
Before you install the switch, review the following considerations about its  
location.  
AT-8948, x900-48FE, x900-48FS, and AT-9900 switches require an ambient  
temperature from 0ºC to 50ºC (32ºF to 122ºF).  
AT-9924Ts, x900-12XT/S, x900-24XT, x900-24XT-N, x900-24XS, and  
SwitchBlade x908 switches require an ambient temperature from 0ºC to  
4
0ºC (32ºF to 104ºF).  
There should be adequate airflow around the switch and its vents.  
The site should be dust-free and without moisture.  
Humidity can be from 5% to 80% non-condensing.  
You need a reliable and earthed (grounded) power supply source, preferably  
dedicated and filtered.  
Cabling must not be exposed to sources of electrical noise, such as radio  
transmitters, broadband amplifiers, power lines, electric motors, and  
fluorescent fixtures.  
Switch ports are suitable for intra-building connections, or where  
non-exposed cabling is required.  
Related network devices can be connected to the switch but cannot exceed  
maximum cable lengths specified in the Hardware Reference.  
You may need to remove cabinet doors from the equipment rack to  
accommodate cords and cables.  
Ensure easy access to the switch’s power and cable connections.  
The SwitchBlade x908 should only be installed in locations where access to  
the system is controlled. The SwitchBlade x908 is not intended for home  
use. If installed in a school, it should only be installed in a location restricted  
to service personnel.  
6

Además del manual Allied Telesis Switch X900-24XS facilitamos un panel de soporte que te ayudará a solucionar tus problemas con Allied Telesis Switch X900-24XS. Si tienes alguna pregunta, puedes escribirla en el formulario más abajo. Otros usuarios que entran aquí tendrán la oportunidad de ayudarte en la solución de tu problema con Allied Telesis Switch X900-24XS. Recuerda que también puedes compartir tu solución. Si has logrado solucionar el problema, por favor escribe aquí la descripción y la solución del problema con Allied Telesis Switch X900-24XS - seguro que ayudarás a muchos usuarios.